Selection Criteria
Authentication List - Select the authentication login list you want to configure. Select 'create' to
define a new login list. When you create a new login list, 'local' is set as the initial authentication
method.
Method 1 - Use the dropdown menu to select the method that should appear first in the selected
authentication login list. If you select a method that does not time out as the first method, such as
'local' no other method will be tried, even if you have specified more than one method. Note that this
parameter will not appear when you first create a new login list. The options are:
Local- the user's locally stored ID and password will be used for authentication
Radius- the user's ID and password will be authenticated using the RADIUS server instead of
locally
Tacacs- the user's ID and password will be authenticated using the TACACS server instead of
locally
Reject- the user is never authenticated
Undefined- the authentication method is unspecified (this may not be assigned as the first
method)
Method 2 - Use the dropdown menu to select the method, if any, that should appear second in the
selected authentication login list. This is the method that will be used if the first method times out. If
you select a method that does not time out as the second method, the third method will not be tried.
Note that this parameter will not appear when you first create a new login list.
Method 3 - Use the dropdown menu to select the method, if any, that should appear third in the
selected authentication login list. Note that this parameter will not appear when you first create a new
login list.
Configurable Data
Authentication List Name - If you are creating a new login list, enter the name you want to assign.
It can be up to 15 alphanumeric characters and is not case sensitive.
Command Buttons
Submit - Sends the updated screen to the switch and causes the changes to take effect on the
switch. These changes will not be retained across a power cycle unless you perform a save.
Delete - Remove the selected authentication login list from the configuration. The delete will fail if the
selected login list is assigned to any user (including the default user) for system login or IEEE 802.1x
port access control. You can only use this button if you have Read/Write access. The change will not
be retained across a power cycle unless you perform a save.