Fortinet FortiSwitch-548B v. 5.2.0.2 Administration Manual page 193

Hide thumbs Also See for FortiSwitch-548B v. 5.2.0.2:
Table of Contents

Advertisement

Syntax
show sflow agent
Default Setting
None
Command Mode
Privilege Exec
Display Message
sFlow Version: Uniquely identifies the version and implementation of this MIB.
IP Address: The IP address associated with this agent.
7.3.13.2 show sflow pollers
The user can go to the CLI Privilege Exec to get the sFlow polling instances created on the switch, use
the show sflow pollers Privilege command.
Syntax
show sflow pollers
Default Setting
None
Command Mode
Privilege Exec
Display Message
Poller Data Source: The sFlowDataSource (slot/port) for this sFlow sampler. This agent will support
Physical ports only.
Receiver Index: The sFlowReceiver associated with this sFlow counter poller.
Poller Interval: The number of seconds between successive samples of the counters associated
with this data source.
7.3.13.3 show sflow receivers
The user can go to the CLI Privilege Exec to get the configuration information related to the sFlow
receivers, use the show sflow receivers Privilege command.
Syntax