Fortinet FortiSwitch-548B v. 5.2.0.2 Administration Manual page 273

Hide thumbs Also See for FortiSwitch-548B v. 5.2.0.2:
Table of Contents

Advertisement

Command Mode
Global Config
7.9.2.3
cdp timer
This command is used to configure an interval time (seconds) of the sending CDP packet.
Syntax
cdp timer <5-254>
no cdp timer
<5-254> - interval time (Range: 5 – 254).
no - This command is used to reset the interval time to the default value.
Default Setting
60
Command Mode
Global Config
7.9.2.4
cdp holdtime
This command is used to configure the hold time (seconds) of CDP.
Syntax
cdp holdtime <10-255>
<10-255> - interval time (Range: 10 – 255).
no - This command is used to hold time to the default value.
Default Setting
180
Command Mode
Global Config
- 273 -