Download Print this page

Snmp-Server Engineid Local - Dell PowerConnect 5316M Reference Manual

Cli reference guide
Hide thumbs Also See for PowerConnect 5316M:

Advertisement

informs — Indicates that SNMP informs are sent to this host.
noauth — Indicates no authentication of a packet.
auth — Indicates authentication of a packet without encrypting it.
priv — Indicates authentication of a packet with encryption.
port — Specifies the UDP port of the host to use. If unspecified, the default UDP port
number is 162. (Range: 1 - 65535)
filtername — Specifies a string that defines the filter for this host. If unspecified, nothing
is filtered. (Range: 1 - 30 characters)
seconds — Specifies the number of seconds to wait for an acknowledgment before
resending informs. If unspecified, the default timeout period is 15 seconds. (Range: 1-
300)
retries — Specifies the maximum number of times to resend an inform request. If
unspecified, the default maximum number of retries is 3. (Range: 1 - 255)
Default Setting
This command has no default configuration.
Command Mode
Global Configuration mode
User Guidelines
A user and notification view are not automatically created. Use the snmp-server user, snmp-
server group and snmp-server view Global Configuration mode commands to generate a user,
group and notify group, respectively.
Example
The following example configures an SNMPv3 host.
Console(config)# snmp-server v3-host 192.168.0.20 john noauth

snmp-server engineID local

The snmp-server engineID local Global Configuration mode command specifies the Simple
Network Management Protocol (SNMP) engineID on the local device. To remove the configured
engine ID, use the no form of this command.
Syntax
snmp-server engineID local {engineid-string | default}
no snmp-server engineID local
230
SNMP Commands

Advertisement

loading