Dell Force10 S4810P Reference Manual page 153

Ftos command line reference guide for the s4810 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

Version 7.6.1.0
Usage
The example below shows the output of the show environment fan command as it
Information
appears prior to FTOS 7.8.1.0.
Example (all)
FTOS#show environment all
-- Fan Status --
-------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
-- Power Supplies --
Unit Bay Status Type
--------------------------------------------
0 0 up AC
0 1 absent
-- Unit Environment Status --
Unit Status Temp Voltage
--------------------------------------------
0* online 50C ok
* Management Unit
-- Fan Status --
Unit Status Speed Fan1 Fan2 Fan3 Fan4 Fan5 Fan6 Serial Num
Version
---------------------------------------------
1 up high up up up up up up 1234 1
Example (fan)
FTOS#show environment fan
-- Fan Status --
---------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
0 up up up up up up up
Example (pem)
FTOS#show environment pem
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------
0 0 up AC
0 1 absent
Example (stack-
FTOS#show environment stack-unit 0
unit)
-- Unit Environment Status --
Unit Status Temp Voltage
--------------------------------------------
0* online 49C ok
* Management Unit
Introduced for the S-Series. S-Series options and output differ from
the C-Series/E-Series version.