camTest

Synopsis
Availability
Description
Operands
Example
Errors
See Also
26
Functional test of the CAM memory.
camTest [passCount]
admin
Use this command to verify that Content Addressable Memory (CAM) is
functionally correct. The CAM is used by QuickLoop to translate the SID.
This command cannot be executed on an operational switch. You
Note
must first disable the switch using the switchDisable command.
This command has the following operand:
Specify the number of times to execute this test. The
passCount
default value is 1. This operand is optional.
To verify that Content Addressable Memory (CAM) is functionally correct:
switch:admin> camTest 2
Running CAM Test .............. passed.
There are three possible error messages if failures are detected:
DIAG-CAMINIT
DIAG-XMIT
DIAG-CAMSID
centralMemoryTest
cmemRetentionTest
cmiTest
crossPortTest
portLoopbackTest
portRegTest
ramTest
spinSilk
sramRetentionTest
Fabric OS Reference Manual