Support for the packet statistics function of the display interface command depends on the device
model. For description of the display interface command, refer to the Ethernet Port Command in the
Access Volume.

Resetting BGP L2VPN Connections

To do...
Reset BGP L2VPN
connections

MPLS L2VPN Configuration Examples

Example for Configuring a Remote CCC Connection

Network requirements
The CEs are connected to the PEs through VLAN interfaces.
A remote CCC connection is created between CE 1 and CE 2.
The main steps for configuring a CCC remote connection are:
Create remote CCC connections on the PEs. No static LSP is required on the PEs.
Configure two static LSPs on the P device for packets to be transferred in both directions.
Figure 1-3 Network diagram for configuring a remote CCC connection
Loop0
Vlan-int10
PE 1
Vlan-int10
CE 1
Device
Interface
CE 1
Vlan-int10
PE 1
Loop0
Vlan-int30
CE 2
Vlan-int10
Configuration procedure
1)
Configure CE 1
Use the command...
reset bgp l2vpn { as-number |
ip-address | all | external |
internal }
Loop0
Vlan-int20
Vlan-int30
Vlan-int30
Vlan-int20
P
Remote CCC connection
IP address
100.1.1.1/24
10.0.0.1/32
10.1.1.1/24
100.1.1.2/24
Loop0
Vlan-int10
PE 2
Vlan-int10
CE 2
Device
Interface
P
Loop0
Vlan-int20
Vlan-int30
PE 2
Loop0
Vlan-int10
1-16
Remarks
Available in user view
IP address
10.0.0.2/32
10.2.2.2/24
10.1.1.2/24
10.0.0.3/32
10.2.2.1/24