through the box. The ventilation holes in each side of the unit must never be
blocked.
There are no spacing requirements above or below the unit.

Desktop Configuration

The ADIC Gateway is shipped with four rubber feet that should be used when the
ADIC Gateway is placed on a desktop or other flat surface. Perform the following
to install the rubber feet.
1. Turn the ADIC Gateway upside down.
2. Remove the backing from the adhesive side. Apply to each of the corners on
the bottom of the ADIC Gateway approximately ¼-inch from each edge. See
Figure 3-1.

Figure 3-1: Installing the Rubber Feet for Desktop Use

Rack Mount Configuration

The ADIC Gateway rack mount kit (included) contains brackets, screws, and
washers that enable it to be mounted in a standard rack. See Figure 3-2. If your
rack does not have threaded rails, you will need to provide clipnuts to complete
the installation. The rack screws that are provided are threaded 10-32. If this does
not match the threaded rails, you will need to provide other screws to complete
the installation. To install into a rack, perform the following:
1. Using one of the brackets, locate the holes you will be using on each side rail
of the rack. Insert the clipnuts (A) if the rails are not threaded.
38
ADIC Gateway Setup