ADIC Scalar 100 User Manual page 285

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

scsiTermGet [channel]
The scsiTermGet command displays termination status information for the
specified channel. If no channel is specified, status information is displayed for all
SCSI channels.
Gateway > scsiTermGet
SCSIbus
SCSI 1
SCSI 2
value = 0 = 0x0
Gateway >
Gateway > scsiTermGet 2
SCSIbus
SCSI 2
value = 0 = 0x0
Gateway >
Information solely about Ultra2/3 SCSI channels may be requested by entering
the xscsiTermGet command.
scsiTermSet [channel],[termination]
The scsiTermSet command enables or disables the termination for the SCSI
Channel.
To set termination status for Ultra 2/3 SCSI Channels only, use the
xscsiTermSet command.
scsiTermGet [channel]
Width
Termination -------
Enabled – default
Enabled
Termination -------
Enabled – default
Parameter
Channel number
Termination
negotiated. A zero in these fields indicates
that asynchronous transfer is in use.
The negotiated transfer width in bits, either 8
or 16.
---------------
---------------
Value
Meaning
1 - 4
Selected Channel
0
Enable Termination
1
Disable Termination
269