Then the burst address test is run. This checks for errors in the memory array's
address logic. The dots represent a test progress display. Each dot represents 1/
16 of the test complete.
Burst Address PCI-0 ..................Passed
Burst Address PCI-1 ..................Passed
The next test is the deep burst test.
RP DMA PCI-0 Passed
RP DMA PCI-1 Passed
The last test looks at data written to one side of the memory and compares it to
data read from the other side.
Data Sharing Passed
An ADIC Gateway without a DDF board will return the following:
=== Testing DDF board ===
** DDF init failure **
value = -1 = 0xfffffff
elTest
elTest is the Ethernet loop back test. The ADIC Gateway must be in diagnostic
mode to use this command and a loop back plug must be installed on the Ethernet
port.
diagmode > elTest
==== Testing Ethernet ====
Init complete.
Ethernet OK
value = 0 = 0x0
The test issues a series of loop back tests. Test data is transferred and verified. A
good test ends with Ethernet OK.