ADIC Scalar 100 User Manual page 202

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

1. If Event Code 69 is repeatedly reported, replace the DDF Board.
See"Removing and Installing the DDF Board" on page 204. If there is a single
occurrence of Event Code 69, proceed with this MAP.
2. Connect the terminal to the Service Port (see "Connecting the Service
Terminal" on page 218).
3. If the ADIC Gateway 's command prompt on the service terminal is not
diagmode>
"Boot Modes" on page 295). Wait for the ADIC Gateway to finish booting.
4. From the service terminal, enter the ddfTest command (see "Diagnostic
Command Reference" on page 295).
5. The ADIC Gateway should respond with a message as shown below:
==== Testing DDF board ====
Bitwalk PCI-0
0 Passed 1 Passed 2 Passed 3 Passed
Bitwalk PCI-1
0 Passed 1 Passed 2 Passed 3 Passed
Access PCI-0
0 Passed 1 Passed 2 Passed 3 Passed 4 Passed 5 Passed 6 Passed
7 Passed
Access PCI-1
0 Passed 1 Passed 2 Passed 3 Passed 4 Passed 5 Passed 6 Passed
7 Passed
Burst PCI-0 Passed
Burst PCI-1 Passed
MemSize PCI-0 is 64 Mbytes
MemSize PCI-1 is 64 Mbytes
Burst Address PCI-0 ................Passed
Burst Address PCI-1 ................Passed
RP DMA PCI-0 Passed
RP DMA PCI-1 Passed
Data Sharing Passed
DDF Test PASSED
value = 0 = 0x0
6. If the test responds with "DDF Board PASSED" then leave this MAP.
7. To eliminate the possibility that other PMC cards are causing an interaction
problem with the DDF, go to "Testing DDF with PMC Cards Removed".