11. From the service terminal, enter the ifShow command (see "Service Port
Command Reference" on page 223).
Gateway > ifShow
lnPci (unit number 0):
Flags: (0x63) UP BROADCAST ARP RUNNING
Internet address: 192.168.1.56
Broadcast address: 192.168.1.255
Netmask 0xffffff00 Subnetmask 0xffffff00
Ethernet address is 00:60:45:0d:00:c1
Metric is 0
Maximum Transfer Unit size is 1500
2 packets received; 4 packets sent
0 input errors; 0 output errors
0 collisions
lo (unit number 0):
Flags: (0x69) UP LOOPBACK ARP RUNNING
Internet address: 127.0.0.1
Netmask 0xff000000 Subnetmask 0xff000000
Metric is 0
Maximum Transfer Unit size is 4096
4 packets received; 4 packets sent
0 input errors; 0 output errors
0 collisions
12. Write down the values of the internet address, netmask, and subnetmask.
13. Compare the internet address with the IP address supplied by the network
administrator. Compare the netmask value with the netmask in hex format
supplied by the network administrator. The subnetmask should be the same
as the netmask. If these values are correct, go to step 15.
14. Otherwise, use the ethAddrSet command to set the correct IP address and
netmask values (see the"ethAddrSet" command on page 236). From the
service terminal, enter the reboot command and wait for the ADIC Gateway
to finish booting. Go back to step 11.
15. Enter the command ping " <host IP address> " , 10 where <host IP
address> is four decimal numbers separated by periods. This is the address
provided by the network administrator for PING testing.
Ethernet MAP