fcShowDevs
The fcShowDevs command displays information about the devices that are
accessible from each Fibre Channel interface. The display shows the LUN that the
ADIC Gateway has assigned to each device, the SCSI Channel that the device is
fcShowDevs
Ready
Sync Lost
Error
Nonparticipating
Failed
Firmware Version
Loop ID
Fabric Attached
Port Mode
and process logins with all
loop ports.
Indicates that the interface is
connected and operational
and ready to process SCSI
commands. Any other value
indicates intermediate
states or interface failure.
The firmware has detected a
loss-of-sync condition and
is re-synchronizing the
serial link receiver. This is
the state reported when the
Fibre Channel link does not
detect a connection to a
Fibre Channel device.
The firmware has detected
an unrecoverable error con-
dition
The firmware is not partici-
pating on the loop since it
did not acquire an AL_PA
during initialization
The firmware is not respond-
ing to commands.
The version of firmware on the Fibre Channel
PMC adapter.
The Fibre Channel Loop ID for this interface.
PtoP indicates a point-to-point connection
Indicates whether the port is attached to a
Fabric.
Indicates whether the port is set to Target or
Initiator mode