ADIC Scalar 100 User Manual page 287

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

presented to the particular operating system. If [port] is 0, the change applies to all
SAN connections; otherwise the host type is applied.
Parameter
Port
OS
setScsiAssign [devID], [channel], [id], [lun]
Assigns a target device to a SCSI channel [channel] with SCSI Target ID [id] and
Logical Unit Number of [lun]. The indicated channel must be configured to be
running in target mode. The [id] and [lun] must be available on that channel.
setSnaCCLun [newLUN]
The setSnaCCLun command reassigns the ADIC Gateway Command and
Control LUN to the specified value.
newLUN is the new value for the Command and Control LUN. Valid values are 0
through 127.
The new setting takes effect immediately. The previous value is removed from the
device map and database and a trap is generated indicating that the device was
removed.
setScsiAssign [devID], [channel], [id], [lun]
Value
0
1 - 6
"nt"
"aix"
"solaris"
"hp-ux"
"netware"
"gateway"
"switch"
"generic"
"unisys"
"as400"
"fcr-2"
"pv-136t-fc"
"autosense
/nt"
Attention: You must reboot the ADIC Gateway after executing this
command for the new setting to take effect.
Changes will apply to all SAN
Connections
Changes will apply to SAN Connection 1
- 6, as specified
271