5. Use the p command to display the contents of the bootline.
[VxWorks Boot]: p
boot device
processor number
file name
inet on ethernet (e) : 10.0.0.41:fffffc00
gateway inet (g)
flags (f)
target name (tn)
startup script (s)
other (o)
6. Note that the startup script reads Bus_Fault_Detected. If this is not
present go to See "ADIC Gateway MAP" on page 182.
7. Change the bootline to allow a diagnostic boot. Use the c command and then
press the Enter key until you reach the flags field. Change flags to 0.
Continue to press the Enter key until you reach the startup script line.
Change the startup script parameters to ffs0:/mt/diagnstk.rc
[VxWorks Boot]: c
'.' = clear field;
boot device
processor number
host name
file name
inet on ethernet (e) : 10.0.0.41:fffffc00
inet on backplane (b):
host inet (h)
gateway inet (g)
user (u)
ftp password (pw) (blank = use rsh):
flags (f)
target name (tn)
startup script (s)
other (o)
Write complete
8. Enter the @ command to start diagnostics boot:
[VxWorks Boot]: @
Data Path Protection MAP
: lnPci
: 0
: ffs0:vxWorkst.Z
: 10.99.2.1
: 0xc
: pl17003
: Bus_Fault_Detected
: lnPci
'-' = go to previous field;
: lnPci
: 0
:
: ffs0:vxWorkst.Z
:
: 10.99.2.1
:
: 0
: pl17003
: ffs0:/mt/diagnstk.rc
: lnPci
^D = quit