hlthChkIntervalGet
- Show Check Interval
hlthChkIntervalSet <interval> - Set Check Interval
hlthChkLevelGet
- Show Check Level
hlthChkLevelSet <level>
- Set Check Level
hlthChkNow
- Run Health Check Now
See User's Guide for more information
value = 0 = 0x0
Gateway >
hlthChkIntervalGet
The current Health Check interval can be viewed using the
hlthChkIntervalGet command. The example below shows the current
interval is 60 minutes.
Gateway > hlthChkIntervalGet
value = 60 = 0x3c = '<'
Gateway >
hlthChkIntervalSet
The Health Check interval controls how often the Health Check process runs. The
interval may range from 1 to 65,535 minutes (about 45 days). Set the interval
using the hlthChkIntervalSet command.
Gateway > hlthChkIntervalSet 60
value = 0 = 0x0
Gateway >
hlthChkLevelGet
To display the current Health Check level, use the hlthChkLevelGet command.
The example below shows that the current level is 2.
Gateway > hlthChkLevelGet
value = 2 = 0x02
Gateway >
hlthChkLevelSet
To set the Health Check level, use the hlthChkLevelSet command. The
example below shows setting the level to 3.
Gateway > hlthChkLevelSet 3
value = 0 = 0x0
246