Event Log Dump; Retrieving The Code 43 Dump File - ADIC Scalar 100 User Manual

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

3. Connect the terminal to the Service Port.
4. From the service terminal, type the hlthChkNow command.
5. Check the results displayed on the service terminal to determine the status of
the interfaces and attached devices. If a failure is indicated, perform the
appropriate MAP.

Event Log Dump

The events that have been logged in the ADIC Gateway's Event Log can be
displayed on the service terminal or viewed from the ADIC Management Console.
This information may be useful because you can see the normal events and any
abnormal events that nay lead you to the source of an internal or external failure.
1. Each entry contains a sequence number, day, and time-stamp, the event
code, event source (interface name or system process), an index, and a
description of the event. If the Real Time Clock has been set, the time-stamp
will be real time. Otherwise, the time stamp will be relative to the boot-time.
2. The Event Log holds more than 2000 events. When the log becomes full, the
oldest events are overwritten by the most recent events.
3. You can choose to view only those events logged since the ADIC Gateway
was last booted or you can view a longer list of events that have accumulated
from previous boots.
4. You can choose to view events by severity level. Selecting
Warning
and
ing
See the loggerDump and loggerDumpCurrent commands in "Connecting to
the Service Port" on page 217.

Retrieving the Code 43 Dump File

If an event code 43 was reported to the ADIC Management Console client, it is an
indication that the ADIC Gateway performed an error recovery operation and had
to reset the Fibre Channel interface to clear a lock-up condition. This event is also
recorded in the ADIC Gateway event log along with the name of a file that was
saved to the flash file system. The file contains information about the state of the
Fibre Channel interface prior to the reset. Follow these steps to retrieve the file.
1. Connect the service terminal to the Service Port (see "Connecting to the Ser-
vice Port" on page 217).