If errors are detected, the test displays the number of bad test iterations as shown
below. If your test was not successful, return to the MAP that sent you here.
diagmode > elTest
==== Testing Ethernet ====
Init complete.
Ethernet timeout error
Ethernet timeout error
Ethernet timeout error
Ethernet timeout error
Ethernet timeout error
Ethernet timeout error
Ethernet test reported 6 errors out of 12 iterations
value = 6 = 0x6
fcSlotTest [x]
The ADIC Gateway must be in diagnostic mode to use this command and a loop
back plug must be connected to the PMC card.
The fcSlotTest command performs a confidence test on a Fibre Channel slot.
Substitute for x the Fibre Channel slot number you want to test. This command
can be used to test the slot or the cable.
The following example code shows the display for a test Fibre Channel slot 1.
diagmode > fcSlotTest 1
FC 1 [##########] Iterations 51 Errors 0 - PASSED
Fibre Channel Port 1 returns PASSED
value = 0 = 0x0
diagmode > fcSlotTest 2
FC 1 [##########] Iterations 51 Errors 0 - PASSED
Fibre Channel Port 2 returns PASSED
value = 0 = 0x0
The following outputs are examples Fibre Channel port tests that were not
successful. If your test was not successful, return to the MAP that sent you here.
U
1
NSUCCESSFUL FIBRE TEST
diagmode > fcSlotTest 1
FC 1 [##########] Iterations 7799 Errors 7799 - FAILED
Fibre Channel Port 1 returns FAILED
value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7
Note: If the Fibre Channel "link" LED does not come on, the test will
not pass.
302
Diagnostic Commands