is typically assigned as 7.
Host ID
You can press the
button to rescan the SCSI bus so the ADIC
Rescan SCSI Bus
Gateway can discover devices that have been added or removed. It also
refreshes the data for the devices on the SCSI channel and updates the display.
is typically enabled. Removing the check mark from this box
Bus Reset on Power Up
disables SCSI bus reset on power-up.
The default
is set automatically by the ADIC Gateway. When
Alternate Initiator ID
the ADIC Gateway scans the SCSI Bus, it determines which IDs are currently
being used by target devices and sets the Alternate ID to the highest ID not in use.
You can change the Alternate ID using the pull-down or typing a new number. To
restore the automatic default selection, choose "-1" from the drop down list.
is typically
. Removing the check mark from this box disables
Termination
Enabled
the internal termination circuits.
Pressing the
button reinitializes the SCSI Channel. This will cause the ADIC
Reset
Gateway to abort all pending commands, reset the channel, and perform a
rescan.
Attention: Use Reset carefully because it causes pending I/O commands to
return failed status back to the host operating system and may have unexpected
results. Make sure all I/O is stopped before issuing this command.
When you are finished viewing or setting SCSI Channel parameters, you may
press
to abort all changes and return to the main screen or you may press
Cancel