Table 5-1: Health Check Levels - ADIC Scalar 100 User Manual

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

allows you to choose how thorough the health check will be when it is
Level
performed. Each level is defined as follows:

Table 5-1: Health Check Levels

Level #
0
1
2
3
4
allows you to enter, in minutes, the amount of time that elapses between
Interval
automatic health checks on the selected ADIC Gateway. The interval can range
from 0 to 65,535 minutes. The default interval is 60 minutes.
Check SAN Gateway Heartbeat
selected ADIC Gateway. A message is displayed on the status line indicating
whether or not a response was received from the ADIC Gateway. Heartbeat
checks are performed automatically at regular intervals.
84
Level Name
None
Basic Function
Interface Test
Device Test
Device Ready
performs a simple communication check on the
Functionality
Health check disabled
Check power supply and temperature
status
Everything from level 1, plus check all
interfaces
Everything from level 2, plus perform
device Inquiry on each target device
Everything from level 3, plus perform Test
Unit Ready on each target device (non-
removable media only)