Table 3-2: Installation Steps
5
Step
6
7
8
9
Installation Checklist
Connect the service
terminal to the Service
Port and start up a
terminal emulation session
User Action or Decision
Turn on the ADIC
Gateway and observe the
startup messages on the
service terminal
Issue the
initializeBox
command from the service
terminal. After issuing this
command, the ADIC
Gateway will reboot
automatically.
If you purchased licenses
for the Data Mover
Module, VPS, or VPM, you
should activate them now
by typing
sncFeatureEnable
vpmFeatureEnable
vpsFeatureEnable
Look for the "done
executing startup script"
message on the service
terminal, then turn off the
ADIC Gateway
See "Connecting to the Service Port" on
page 217.
Comments and References
Look for "done executing startup script"
message (See "Startup Message
Reference" on page 315)
Within one minute, the Ready LED
should start flashing once per second.
If the "done executing startup script"
message is not seen or the Ready LED
is not flashing as expected, go to "Start
MAP" on page 157
See "Service Port Command Reference"
on page 223.
Attention: This command will erase all
configuration information. It should be
used only during initial ADIC Gateway
installation
see Appendix B: Service Port Command
Reference
None