sysVpdShow or sysVpdShowAll
The sysVpdShow command displays Vital Product data information. The Vital
Product Data for the ADIC Gateway includes such items as serial numbers and
installed memory sizes, as shown below.
Gateway > sysVpdShow
====== VPD ======
name SAN Gateway
uid
00:60:45:16:01:04
s/n
100111
mfg
DISC, Inc.
board OntarioII 1.1
" s/n 08357659
flash 2Mbyte
dram 32Mbyte
slot1 10772100 FCOSW
scsi 1: DET 2: DET
EC
OTA08000H
RID Tag
value = 0 = 0x0
Gateway >
The fields are:
sysVpdShow or sysVpdShowAll
•
The product's Name, up to 16 characters
•
The product's unique Ethernet MAC address, 32 characters dis-
played as hexadecimal bytes separated by colons
•
The product's serial number, up to 16 characters
•
The product's manufacturer, up to 16 characters
•
The name of the motherboard contained in the base unit, up to 16
characters
•
The motherboard's serial number, up to 16 characters
•
The size of the FLASH memory on the motherboard
•
The size of the DRAM on the motherboard
•
The GBIC type installed in SAN Connection slot one
•
The SCSI type for each of the two channels, DET for "Differential,
terminated" and SET for "Single-ended, terminated"
•
The Engineering Change (EC) level for the motherboard, up to 16
characters
•
The RID Tag identifier, up to 16 characters
277