Table 3-2: Installation Steps
10
11
Step
12
13
13
14
34
The SCSI disk or tape
subsystems must be
installed and verified
before the ADIC Gateway
installation can continue
Connect the SCSI cables
from the target devices to
the ADIC Gateway.
Turn on the SCSI target
devices
User Action or Decision
Turn on the ADIC
Gateway
Issue the targets
command from the service
terminal.
Configure the Ethernet
Port (Host Name, Address,
Routes, Enable Ethernet,
reboot).
Connect the Ethernet
cable from the network hub
to the ADIC Gateway
Observe Ethernet Link
LED
Issue hostTypeShow
command from the service
terminal to view host type
settings for the Fibre
Channel ports.
If the hosts that will be
connected are not the type
shown, issue setHost
command from the service
terminal to set the host
type for each Fibre
Channel port
None
Go to "Attaching SCSI Devices" on
page 39
Comments and References
Within one minute, the Ready LED
should start flashing once per second
and the "done executing startup script"
message should be displayed on the
service terminal
See "Appendix B: Service Port
Command Reference".
If all attached SCSI targets are not
shown, go to "SCSI MAP" on page 171
Configure the Ethernet Port using
information from Step 8, Table 3-1: "Pre-
Installation Steps" on page 29.
Go to "ADIC Gateway Network Setup" on
page 49.
If the Ethernet Link LED is not on, go to
"Ethernet MAP" on page 187
See ""setHost [port],"OS"" on page 270".
If the Virtual Private SAN access control
option will be installed, VPS will
configure the host type for each host and
override the Fibre Channel port host type
settings
Installation Checklist