Configure the Modbus gateway

Required configuration items
Server configuration:
n
Enable the server.
l
Connection type, either socket or serial.
l
If the connection type is socket, the IP protocol to be used.
o
o
If the connection type is serial, the serial port to be used.
Client configuration:
n
Enable the client.
l
Connection type, either socket or serial.
l
If the connection type is socket:
o
The IP protocol to be used.
o
The hostname or IPv4 address of the remote host on which the Modbus server is
o
running.
If the connection type is serial:
o
o
The serial port to be used.
Modbus address or addresses to determine if messages should be forwarded to a
l
destination device.
Additional configuration items
Server configuration:
n
The packet mode.
l
The maximum time between bytes in a packet.
l
If the connection type is set to socket:
l
The port to use.
o
The inactivity timeout.
o
o
Access control list.
If the connection type is set to serial:
l
o
Whether to use half duplex (two wire) mode.
Client configuration:
n
The packet mode.
l
The maximum time between bytes in a packets.
l
Whether to send broadcast messages.
l
Response timeout
l
If connection type is set to socket:
l
o
The port to use.
The inactivity timeout.
o
If connection type is set to serial:
l
Whether to use half duplex (two wire) mode.
o
IX10 User Guide
Modbus gateway