Digi IX10 User Manual page 731

Hide thumbs Also See for IX10:
Table of Contents

Advertisement

User authentication
3. Click Authentication.
4. For Idle timeout, enter the amount of time that the active session can be idle before the user
is automatically logged out.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Idle timeout to ten minutes, enter 10m or 600s.
5. Click Apply to save the configuration and apply the change.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX10
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. At the config prompt, type:
(config)> auth idle_timeout value
where value is any number of weeks, days, hours, minutes, or seconds, and takes the format
number{w|d|h|m|s}.
For example, to set idle_timeout to ten minutes, enter either 10m or 600s:
IX10 User Guide
Set the idle timeout for IX10 users