<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] state secondary authentication block
Related commands
display radius scheme
radius-server test-profile
server-load-sharing enable
state primary
timer quiet (RADIUS scheme view)
Use timer quiet to set the quiet timer for the servers specified in a RADIUS scheme.
Use undo timer quiet to restore the default.
Syntax
timer quiet minutes
undo timer quiet
Default
The server quiet timer period is 5 minutes in a RADIUS scheme.
Views
RADIUS scheme view
Predefined user roles
network-admin
Parameters
minutes: Specifies the server quiet period in minutes, in the range of 1 to 255.
Usage guidelines
Make sure the server quiet timer is set correctly.
A timer that is too short might result in frequent authentication or accounting failures. This is because
the device will continue to attempt to communicate with an unreachable server that is in active state.
A timer that is too long might temporarily block a reachable server that has recovered from a failure.
This is because the server will remain in blocked state until the timer expires.
Examples
# In RADIUS scheme radius1, set the quiet timer to 10 minutes for the servers.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] timer quiet 10
Related commands
display radius scheme
timer realtime-accounting (RADIUS scheme view)
Use timer realtime-accounting to set the real-time accounting interval.
Use undo timer realtime-accounting to restore the default.