INVT Goodrive300 Series Operation Manual page 42

Vfd
Table of Contents

Advertisement

Goodrive300 Series VFD
are: set frequency, bus voltage, input terminals state, output terminals state, PID given value, PID
feedback value, torque set value, AI1, AI2, AI3, HDI, PLC and the current stage of multi-step speeds,
pulse counting value, length value. P07.07 can select the parameter to be displayed or not by bit
and 》/SHIFT can shift the parameters form left to right, QUICK/JOG (P07.02=2) can shift the
parameters form right to left.
5.3.2 Displayed state of running parameters
After the VFD receives valid running commands, the VFD will enter into the running state and the
keypad will display the running parameters. RUN/TUNE LED on the keypad is on, while the
FWD/REV is determined by the current running direction which is shown as figure 5-2.
In the running state, there are 24 parameters can be selected to be displayed or not. They are:
running frequency, set frequency, bus voltage, output voltage, output torque, PID given value, PID
feedback value, input terminals state, output terminals state, torque set value, length value, PLC and
the current stage of multi-step speeds, pulse counting value, AI1, AI2, AI3, HDI, percentage of motor
overload, percentage of VFD overload, ramp given value, linear speed, AC input current. P07.05 and
P07.06 can select the parameter to be displayed or not by bit and 》/SHIFT can shift the parameters
form left to right, QUICK/JOG (P07.02=2) can shift the parameters from right to left.
5.3.3 Displayed state of fault
If the VFD detects the fault signal, it will enter into the fault pre-alarm displaying state. The keypad will
display the fault code by flicking. The TRIP LED on the keypad is on, and the fault reset can be
operated by the STOP/RST on the keypad, control terminals or communication commands.
5.3.4 Displayed state of function codes editing
In the state of stopping, running or fault, press PRG/ESC to enter into the editing state (if there is a
password, see P07.00).The editing state is displayed on two classes of menu, and the order is:
function code group/function code number→function code parameter, press DATA/ENT into the
displayed state of function parameter. On this state, you can press DATA/ENT to save the parameters
or press PRG/ESC to retreat.
PRG
ESC
QUICK
JOG
RUN
Stop parameters display
DATA
PRG
ENT
ESC
QUICK
JOG
SHIFT
STOP
RUN
RST
Running parameters display
Figure 5-2 Displayed states
DATA
ENT
SHIFT
STOP
RST
37
Keypad operation procedure
PRG
DATA
ESC
ENT
QUICK
JOG
SHIFT
STOP
RUN
RST
Fault display

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300 Series and is the answer not in the manual?

Questions and answers

Table of Contents