7.16 Traverse running

Traverse is applied in some industries such as textile, chemical fiber and cases where traverse and
convolution is required. The working flowchart is as below:
Keypad
P00.10
Keypad setting
AI1
frequency
AI2
AI3
HDI
Simple PLC
Multi-stage
PID
MODBUS
PROFIBUS
Ethernet
CAN
Name
Setting frequency
PID reference
PID feedback
P00.06
(A frequency command selection)
Traverse range
0
P08.05
1
2
3
4
*
5
*
6
7
8
9
10
11
Detailed instruction of parameters
the trend between the reference and the
feedback changes, the integration will
change with the trend quickly.
LED tens: P00.08 is 0
0: The same with the setting direction; if
the output of PID adjustment is different
from the current running direction, the
internal will output 0 forcedly.
1: Opposite to the setting direction
LED hundreds: P00.08 is 0
0: Limit to the maximum frequency
1: Limit to frequency A
LED thousands:
0: A+B frequency, the buffer of A
frequency is invalid
1: A+B frequency, the buffer of A
frequency is valid
ACC/DEC is determined by ACC time 4
of P08.04
0.00Hz–P00.03 (Max. frequency)
-100.0–100.0%
-100.0–100.0%
Keep the current frequency
Setting
Valid
frequency
Invalid
Terminal
function 26
Traverse
pause
182
Basic operation instruction
Valid
Invalid
Terminal
function 27
P00.11 ACC time 1
Traverse
P00.12 DEC time1
Default
value
0.00Hz
0.0%
0.0%
Traverse
output