Goodrive300 Series VFD
0
1
P05.00
(HDI input type selection )
0: HDI is high speed pulse
P05.00
input
1: HDI is digital input
Related parameters
Function
code
P05.00
P05.32
Corresponding setting of
P05.33
the lower limit of AI1
P05.34
Corresponding setting of
P05.35
the upper limit of AI1
P05.36
P05.37
Corresponding setting of
P05.38
the lower limit of AI2
P05.39
Corresponding setting of
P05.40
the upper limit of AI2
P05.41
P05.42
Corresponding setting of
P05.43
the lower limit of AI3
AI1
AI2
AI3
0
HDI
1
2
P05.49
(HDI high speed pulse input function selection )
0: Frequency setting
P05.49
input
1-2: Reserved
Name
HDI input selection
Lower limit of AI1
Upper limit of AI1
AI1 input filter time
Lower limit of AI2
Upper limit of AI2
AI2 input filter time
Lower limit of
AI3
AI1 input voltage
Analog input curve setting
P17.19
P05.32
P05.33
P05.34
AI2 input voltage
P05.35
P17.20
P05.37
P05.38
P05.39
AI3 input voltage
P05.40
P17.21
P05.42
P05.43
P05.44
P05.45
P05.46
HDI input frequency
P05.47
P17.22
P05.50
P05.51
P05.52
P05.53
Detailed instruction of parameters
0: High pulse input.
1: Digital input.
0.00V–P05.34
-100.0%–100.0%
P05.32–10.00V
-100.0%–100.0%
0.000s–10.000s
0.00V–P05.39
-100.0%–100.0%
P05.37–10.00V
-100.0%–100.0%
0.000s–10.000s
-10.00V–P05.44
-100.0%–100.0%
157
Basic operation instruction
AI3
AI1/AI2/
HDI
Analog input filter
P05.36
P05.41
P05.48
P05.54
Default
value
0
0.00V
0.0%
10.00V
100.0%
0.100s
0.00V
0.0%
10.00V
100.0%
0.100s
-10.00V
-100.0%
Need help?
Do you have a question about the Goodrive300 Series and is the answer not in the manual?
Questions and answers