Goodrive300 Series VFD
Function
instruction
Fault code of the
VFD
Identifying code
of the VFD
Operation
frequency
Setting freqency
Bus voltage
Output voltage
Output current
Rotation speed
Output power
Output torque
Close loop
setting
Close loop
feedback
Input IO state
Output IO state
Analog input 1
Analog input 2
Analog input 3
Analog input 4
Read input of
high-speed pulse
1
Read input of
high-speed pulse
2
Read the current
stage of
multi-step speed
External length
External
counting
Address
definition
2102H
See the fault type instruction
2103H
GD300-----0x010a
3000H
0–Fmax(unit: 0.01Hz)
3001H
0–Fmax(unit: 0.01Hz)
3002H
0.0–2000.0V (unit: 0.1V)
3003H
0–1200V (unit: 1V)
3004H
0.0–3000.0A (unit: 0.1A)
3005H
0–65535 (unit: 1RPM)
3006H
-300.0–300.0% (unit: 0.1%)
3007H
-250.0–250.0% (unit: 0.1%)
3008H
-100.0–100.0% (unit: 0.1%)
3009H
-100.0–100.0% (unit: 0.1%)
300AH
000–1FF
300BH
000–1FF
300CH
0.00–10.00V (unit: 0.01V)
300DH
0.00–10.00V (unit: 0.01V)
300EH
0.00–10.00V (unit: 0.01V)
300FH
3010H
0.00–50.00kHz (unit: 0.01Hz)
3011H
3012H
0–15
3013H
0–65535
3014H
0–65535
Data meaning instruction
=01: terminal contorl
=10: communication control
220
Communication protocol
R/W
characteristics
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R