Standard value of mis-centring: within 3mm
Centre of image
Within 3 mm
Centre of paper
4.
Setting the LCT Rear Guide (C-404 only)
Rear guide
Screws
a.
Adjustment method
Step
Open the top cover.
1
Press SW100 (LT tray down switch) to
2
lower the up/down plate to the bottom.
Loosen two screws at the top of the rear
3
guide and one screw at the bottom.
Set paper on the up/down plate, align
the trailing edge of paper with the lower
4
end of the rear guide, then fasten the
lower screw.
Fasten the two upper screws temporarily
and move the up/down plate to the high-
5
est position.
Set paper on the up/down plate, align
the trailing edge of paper with the upper
6
end of the rear guide, then tighten the
two upper screws finally.
Reference: LCT tray size setting can be per-
formed in the key operation mode
by setting DIPSW21-1 to 1 in the 25
mode.
2-103