ADJUSTMENT
3. Multi mode
This machine features Multi modes amongst the
47 Mode functions.
This enables multiple I/O checks using a single I/
O check code.
4. Multi mode operation method
Start the 47 mode and proceed as follows:
(1) To check the input
a.
Using the copy quantity button, enter the check
code for the desired I/O.
b.
The 47 mode code appears enclosed in <> in the
second row of the message area.
c.
Press the Utility button.
d.
Enter the desired multi number using the copy
quantity button. (Refer to the multi mode list.)
e.
The multi number will be displayed enclosed in
<>, following the 47 mode code and "- ".
I/O check mode
< 10-01 > IN: -- OUT: --
f.
Press the Utility button.
g.
Check the status of the signal displayed as H or
L after "IN:" in the second row of the message
display area.
(2) To check the output
a.
Press the START button.
b.
Press the STOP button after checking the output.
(3) Ending multi mode
a.
Turn off the main switch to exit the 47 mode (multi
mode).
Step
1
Enter the 47 mode.
[I/O check Screen]
Use the copy quantity button and enter the
2
code.
Press the Utility button.
3
Enter the multi number using the copy
4
quantity button.
5
Press the Utility button.
Check the input signal check result dis-
played after "IN:" in the second row of the
6
message area.
To perform the output check, press the
7
Start button to check the output load.
Press the STOP button to end the output
8
check.
Turn off the main switch to exit the 47 mode.
9
Note1: To check another multi number in the
same code, press the Utility button after
completing step 8. And enter another
multi number. A newly entered number
is written over the previously entered
number.
Note2: To return to the normal 47 mode, press
the STOP button while holding down
the Utility button after completing step
8.
2-88