CORONA UNIT SECTION
[1] Composition
<Charging corona unit>
1
1.
Charging control plate
2.
Charging corona wire
3.
Charging wire cleaning motor (M14)
4.
PCL
5.
Transfer entrance guide plate
[2] Mechanisms
Mechanism
Charging
Scorotron (DC negative
corona discharge)
Discharging wire: Tungsten,
0.06 mm dia. (gold-plated skin
path, with automatic wire
cleaner)
Grid control: Gold-plated
stainless plate
Transfer
DC positive corona discharge
Discharging wire: Oxide film
tungsten, 0.06 mm dia., with
automatic wire cleaner
Separation
AC/DC corona discharge
Discharging wire: Oxide film
tungsten, 0.06 mm dia., with
automatic wire cleaner
2
4
3
Method
2-F-1
CORONA UNIT SECTION
<Transfer and separetion corona unit>
5
10
9
6.
Guide rollers
7.
Transfer corona wire
8.
Plunging prevention plate (front)
9.
Separation corona wire
10. Plunging prevention plate (rear)
6
7
8