Minolta Di551 Service Manual page 318

Hide thumbs Also See for Di551:
Table of Contents

Advertisement

*25 Selection of area to be erased in non-original
area automatic erasure
These bits are used to make a setting associated
with the non-original automatic erasure mode
(application function).
Mode
Standard
Dark original
Coping with light interfer-
ence
*26 Weekly timer summer time setting
Mode
17-3
0 minute
0
10 minutes
0
20 minutes
0
30 minutes
0
40 minutes
0
50 minutes
0
60 minutes
0
70 minutes
0
80 minutes
1
90 minutes
1
100 minutes
1
110 minutes
1
120 minutes
1
130 minutes
1
140 minutes
1
150 minutes
1
*27 Density selection for scanning tab paper
The higher the brightness level, the higher the
density.
Mode
80 (brightness level)
40
60
100
120
160
200
255(not clipped)
16-6
16-5
0
0
0
1
1
0
17-2
17-1
17-0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
17-6
17-5
17-4
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
2-21
*28 Fixing temperature setting switch over
This setting is performed to change fixing tem-
perature when fixing is insufficient or paper curl
is excessive.
This setting is effective only when standard
paper is used. Therefore, it is not applied when
thick or thin paper is used or temperature is spec-
ified in power mode.
• Standard
Standard setting value
• Standard+α Set when fixing is insufficient
• Standard-α Set when paper curl is excessive
Mode
Standard
Standard+5°C
Standard+10°C
Standard+15°C
Standard-5°C
Standard-10°C
Standard-15°C
Standard+20°C
*29 IP scanner default resolution
Mode
400dpi
600dpi
200dpi
300dpi
*30 Number of punched holes
Mode
2 holes (Japan)
3 holes (Inch area)
4 holes (Metric area)
ADJUSTMENT
19-3 19-2 19-1
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
19-7 19-6
0
0
0
1
1
0
1
1
22-2 22-1
0
0
0
1
1
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di650

Table of Contents