Developing Unit; Screws That Must Not Be Removed; Removing And Reinstalling The Developing Unit - Minolta Di551 Service Manual

Hide thumbs Also See for Di551:
Table of Contents

Advertisement

DEVELOPING UNIT

[1] Screws that must not be Removed

a.
Procedure
(1) Two screws securing the toner transfer regula-
tion plate.
(2) One screw securing the magnet angle adjusting
knob.
Screws that must not be removed
Screws that must not be removed
[2] Removing and Reinstalling the Devel-
oping Unit
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Draw out the drum unit from the main body. (See
"DRUM UNIT.")
(2) Release the toner supply pipe.
(3) Release the developing unit push pressure lever.
(4) Supporting the developing unit at the positions
shown below with both hands, remove it from the
drum unit.
Toner supply pipe
Developing unit push
pressure lever
(5) Reinstall the above parts following the removal
steps in reverse.