[8] Removing and Reinstalling the Trans-
fer/Separation Corona Unit
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Draw the ADU frame from the main body. (See
"ADU UNIT.")
(2) Loosen two screws to remove the transfer/sepa-
ration corona unit.
Screw
(3) Reinstall the above parts following the removal
steps in reverse.
Caution: When installing the transfer/separa-
tion corona unit, make sure the clean-
ing gear coupling is engaged properly.
[9] Removing and Reinstalling the
a.
(1) Draw the ADU frame from the main body. (See
(2) Remove the transfer/separation corona unit.
(3) Release the six locks and remove the plunger
(4) Release the six locks and remove the plunger
Screw
Transfer/separation
(5) Reinstall the above parts following the removal
corona unit
1-F-5
Plunger Prevention Plate
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
Procedure
"ADU UNIT.")
prevention plate (front).
prevention plate (rear).
plunger prevention plate (front)
plunger prevention
plate (rear)
Lock
Lock
(Same as on the opposite side)
steps in reverse.