ADJUSTMENT
(8) Collecting data No.10: SC count / Collecting data No.12: SC count of each section (can be reset)
Trouble
NO
code
Paper feed MT EM
1
13
1
LCT conveyance MT EM
2
13
2
Tray 1 up MT EM
3
18
10
Tray 1 up error
4
18
11
Tray 2 up MT EM error
5
18
20
Tray 2 up error
6
18
21
Tray 3 up MT EM error
7
18
30
Tray 3 up error
8
18
31
Tray 4 up MT EM error (Japan only)
9
18
40
Tray 4 up error (Japan only)
10
18
41
LCT up/down MT EM
11
18
50
LCT up/down error
12
18
51
By-pass tray up error
13
18
60
Charging corona unit cleaning MT error 1
14
21
1
Charging corona unit cleaning MT error 2
15
21
2
Charging corona unit cleaning MT error 3
16
21
3
Charging corona unit cleaning MT error 4
17
21
4
Transfer/separation corona unit cleaning MT
18
21
5
error 1
Transfer/separation corona unit cleaning MT
19
21
6
error 2
Transfer/separation corona unit cleaning MT
20
21
7
error 3
Transfer/separation corona unit cleaning MT
21
21
8
error 4
Developing suction fan lock
22
22
1
Cleaner cooling fan lock
23
22
2
Toner bottle MT EM
24
23
1
Developing MT EM
25
23
2
Drum MT error
26
23
3
Charging EM
27
28
1
Transfer EM
28
28
2
Separation EM
29
28
3
Maximum density correction error 1
30
29
1
Maximum density correction error 2
31
29
2
Maximum density correction error 3
32
29
3
γ correction error 1
33
29
4
γ correction error 2
34
29
5
γ correction error 3
35
29
6
Dot diameter correction error 1
36
29
7
Dot diameter correction error 2
37
29
8
Conveyance suction fan lock
38
32
1
Paper exit fan/2 lock
39
32
2
Paper exit fan/R lock
40
32
3
Paper exit fan/F lock
41
32
4
Description
2-36
Maximum
Remarks
count
All counters are 4-
9999
digit counters.