Reinstalling The Radf - Minolta Di551 Service Manual

Hide thumbs Also See for Di551:
Table of Contents

Advertisement

EDH
(7) Close the RADF. Remove three screws to detach
each of two fixing plates.
Fixing plate
Screw
(8) Open the RADF to the upright position.
(9) Remove two screws to detach the spacer and
attachment from the left fixing plate.
(10) Holding the RADF, remove four screws to detach
two fixing plates and remove the RADF from the
main body.
Caution: When fixing plates are removed, the
RADF may fall down to the rear side.
Be sure to hold the RADF.
1.
Fixing plate
2.
Screws
3.
Spacer
4.
Attachment
Fixing plate
Screws (2)
1
2
2
3
2
4
1
1-P-2

[2] Reinstalling the RADF

Caution:
Make sure power cord of the main unit has
been unplugged from the wall outlet.
a.
Procedure
(1) Place the RADF on the top of the main unit and
loosely secure each of the two fixing plates with
four screws.
(2) Secure the attachment and spacer to the left fix-
ing plate, and loosely secure it with two screws.
(3) Remove two screws to detach the original stop-
per plate (left).
6
3
6
1.
Fixing plate
2.
Screws (tighten temporarily)
3.
Original stopper plate (left)
4.
Attachment
5.
Spacer
6.
Screws
(4) Follow the removal procedure in reverse, install
the cable conduit and four relay connectors
(CN612 to CN615).
1
2
1
4
5
2

Advertisement