CORONA UNIT
[6] Removing and Reinstalling the PCL
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Remove the charging corona unit.
(2) Disconnect the wire binding band at two loca-
tions.
(3) Release the lock and remove the PCL.
PCL
Lock
PCL
Wire binding band
(4) Reinstall the above parts following the removal
steps in reverse.
2
1
PCL
1-F-4
[7] Cleaning the Charging Corona Unit/
PCL
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Remove the charging corona unit.
(2) Remove the charge control plate and PCL.
(3) Place the charge control plate on a flat surface
and clean by gently tapping with a cleaning pad
moistened with drum cleaner. Next, remove any
remaining dirt with a blower brush.
Caution: Take care not to damage the mesh of
the charge control plate during clean-
ing.
(4) Clean the PCL with a cleaning pad moistened
with drum cleaner.
Charging corona unit and control plate
PCL