[12] Removing and Reinstalling the Fixing
Temperature Sensors 1 and 2
Caution1: After reinstalling fixing temperature
sensor 2, make sure that the sensor
touches the fixing upper roller.
Caution2: Make sure the sensor wires do not
touch the fixing upper roller.
Caution3: When reinstalling fixing temperature
sensor 1, adjust its position using the
positioning jig (4024-2990-01) and
secure it with screws. Be sure to apply
screw lock agent to the screws. This
adjustment should be made in a
pressured state.
a.
Removal procedure
(1) Remove the fixing unit.
(2) Remove the web cover.
(3) Remove the cleaning web.
(4) Disconnect the two relay connectors (fixing tem-
perature sensor 1, CN52; fixing temperature
sensor 2, CN53) and release the sensor wires
from the cable guides.
(5) Remove two screws to detach fixing temperature
sensor 1.
(6) Remove one screw to detach fixing temperature
sensor 2.
1
4
1.
Screws
2.
Fixing temperature sensor 2
3.
Fixing temperature sensor 1
4.
Fixing temperature sensor 1 (CN52)
5.
Fixing temperature sensor 2 (CN53)
2
1
3
5
1-O-9
b.
Reinstallation procedure
(1) Secure fixing temperature sensor 2 to the fixing
plate with a screw.
(2) Make sure that fixing temperature sensor 2
touches the fixing upper roller. If they do not
touch each other, be sure to bring the sensor in
contact with the roller.
(3) Set a fixing temperature sensor positioning jig
between fixing temperature sensor 1 and fixing
upper roller, and secure fixing temperature sen-
sor 1 with two screws so that the distance
between the sensor and roller is equal to the
thickness of the jig.
The fixing temperature
sensor 2 must contact
the fixing upper roller.
3
5
1.
Screws
2.
Fixing temperature sensor 2
3.
Fixing upper roller
4.
Fixing temperature sensor 1
5.
Positioning jig (4024-2990-01)
FIXING UNIT
1
2
1
4