ADU UNIT
[8] Removing and Reinstalling the Pre-
transfer Roller
Warning:
The interlock which is turned OFF when
the front right or left door opens or closes
should never be turned ON forcibly with
the ADU stand drawn out.
Caution:
Be sure the power cord has been
unplugged from the wall outlet.
a.
Procedure
(1) Draw out the ADU stand from the main body.
(2) Remove the two springs.
(3) Open the pre-transfer jam handler to remove the
pre-transfer roller assembly.
1
3
1.
Pre-transfer roller assembly
2.
Pre-transfer jam handler
3.
Springs
(4) Remove the E-ring to remove the pre-transfer
roller from the shaft.
Caution: When reinstalling, pay attention to the
(5) Reinstall the above parts following the removal
steps in reverse.
2
1-N-6
position of the E-ring.
Pre-transfer roller
Shaft
E-ring