Replacing The Exposure Lamp - Minolta Di551 Service Manual

Hide thumbs Also See for Di551:
Table of Contents

Advertisement

SCANNER SECTION
(3) Remove the connector (CN170) from the A/D
converter board (ADB).
A/D converter board (ADB)
(4) Remove two screws to remove the CCD unit.
Marking
CCD unit
Caution: Mark the place where the CCD unit is
installed before removing it.
(5) Reinstall the above parts following the removal
steps in reverse.
CCD unit
Connector (CN170)r
Screws
Marking
1-C-2

[3] Replacing the Exposure Lamp

Caution1:
Be sure the power cord has been
unplugged from the wall outlet.
Caution2:
Do not touch the exposure lamp with bare
hands.
Caution: Be sure to check the image after
installing the exposure lamp. (See
"ADJUSTMENTS.")
a.
Procedure
(1) Remove the original stopper plates (left and
rear), platen glass and top cover (right, middle
front, and middle rear). (See "EXTERNAL SEC-
TION.")
(2) Move the exposure unit to the notch in the main
body frame on the paper exit side.
(3) Remove the connector and two screws, then
remove the exposure lamp.
Connector
Exposure lamp
(4) Reinstall the above parts following the removal
steps in reverse.
Screws
Screws