Resetting The Circuit Breaker - Minolta Di551 Service Manual

Hide thumbs Also See for Di551:
Table of Contents

Advertisement

EXTERNAL SECTION

[5] Resetting the Circuit Breaker

Caution:
Be sure the power cord has been
unplugged from the wall outlet.
Caution:
Connection of cables to circuit breaker 1
and 2 (CBR1, 2) must not be changed.
a.
Procedure
(1) Remove the rear cover.
(2) Remove two screws and loosen the circuit
breaker assembly.
1
2
9
1.
Noise filter (NF)
2.
Faston (FT3: noise filter side/black cable)
3.
Circuit breaker 1 (CBR1)
4.
Screws (2)
5.
Faston (FT1: wall outlet side/black cable)
6.
Circuit breaker assembly
7.
Circuit breaker 2 (CBR2)
8.
Faston (FT2: wall outlet side/white cable)
9.
Faston (FT4: noise filter side/white cable)
(3) Turn over the circuit breaker assemblies and
press the reset button at the center of each circuit
breaker.
(4) Reinstall the above parts following the removal
steps in reverse.
3
4
5
6
7
8
1-A-6