[3] Copying Transfer Data (Update Data)

Run the ISW Trns program to copy transfer data
(update data) to the PC.
Step
Procedure
1
Boot the PC.
2
Select ISW Trns from the Start menu to run
the ISW Trns program.
3
Click the Option menu.
4
[Option window]
Click Data Copy.
5
[File Copy window]
Mount an update disk on the PC and click
Browse.
6
Select the folder on drive A that contains the
transfer file (update data) as a source file.
Note1: The selected folder is displayed in
the upper section in the Original
Files field.
Note2: The transfer files (update data) that
are stored in the selected folder are
displayed in the lower section in the
Original Files field.
7
Select the transfer files (update data) you
want copied from the lower section in the
Original Files field.
Note1: You can select multipletransfer files
(update data).
Note2: To copy all the files (update data)
displayed, skip this step to go to
Step 8 directly.
Step
8
Click Copy to copy the selected transfer files
(update data) to the folder created at ISW
Trns setup.
Note1: To copy all the files (update data)
displayed in the Original Files field,
click Copy All, instead of Copy.
Note2: The folder name created at ISW
Trns setup is displayed above the
Copied File field.
Note3: The transfer files that have been
copied successfully so far are listed
in full-path name in the lower part of
the Copied File list view.
The transfer files that have not been
copied successfully are listed in the
Failed to Copy Files list view.
Causes of copy errors:
1. A file with the same name existed
and the O/W (overwrite) check
box was not checked.
2. The storage destination folder
could not be found.
3. Attempted to overwrite an over-
write protected file.
Note4: To update existing transfer files
(update data), check the O/W (over-
write) check box.
9
When the copying completes, click Refresh.
10 If more update disks are involved, repeat
Steps 5 to 9.
11 Click Cancel to return to the option window.
12 [Option window]
Click OK.