GRAPHTEC CE7000-40 Service Manual page 229

Cutting plotter
Hide thumbs Also See for CE7000-40:
Table of Contents

Advertisement

Error
Error Display
code
E04020
E04021
E04022
E04023
E04024
E04025
E04026
E04027
E04028
CE7000-UM-251-9370
Cause
This error is displayed when
the abnormal registration
marks are detected.
This error is displayed when
the 1st registration mark
was not detected in the auto
detection area.
There was cancel operation by
the user.
Registration mark was not
detected.
Registration mark was not
detected.
This error is displayed when
the rotation was set to ON with
the segment registration mark
operation.
This error is displayed when
the mirror was set to ON with
the segment registration mark
operation.
Amount of data has exceeded
the ARMS buffer size for the
segment area registration
mark.
26
9
TROUBLESHOOTING
Solution
Confirm position of registration mark
and the cutting data.
Check the media. Check the print
position of the registration mark.
Redo the process.
Redo the sensor level adjustment.
Change the color of the registration
mark.
Check the media.
Check the print position of the
registration mark.
Redo the sensor level adjustment.
Change the color of the registration
mark.
Check the media.
Check the print position of the
registration mark.
Set the rotation setting to OFF.
Set the mirror setting to OFF.
Decrease the data.