"Precision Farming" fault table
Fault
Fault title
number
PF-100
GPS receiver
communication
lost
PF-101
GPS receiver
position lost
PF-102
Working without
task selected
PF-103
Memory device not
detected
PF-104
Memory device
removed
PF-105
Memory device
90% full
PF-106
Memory device full Data logging disabled. Archive data on
PF-107
Task file is full.
PF-108
Map memory
exceeded
PF-109
Area calibration not
valid
8 - DIAGNOSTICS
Advisory message
Position data not available until
communication restored. Check display
"connection type." Recycle power. If
problem continues, contact dealer.
GPS Receiver Unable to Determine
Position. Ensure GPS antenna is not
obstructed.
An active grower, farm, field, and task
must be selected before data can be
logged. (Home > Performance > Profile)
Data logging disabled. Insert memory
device and recycle power to enable data
logging.
Data logging disabled. Insert memory
device and recycle power to enable data
logging.
Archive data on memory device and
remove unwanted files via Home> Data
Management > Delete screen.
data card and remove unwanted files
via Home > Data Management > Delete
screen.
The current active task has reached the
maximum file size.
Warning – New data will be recorded but
not shown on display map.
The area calibration is out of the
acceptable range.
8-9
Action
The system has lost communication
with the GPS receiver. Ensure that
the proper connection type has been
selected for the vehicle type (Home >
Toolbox > GPS). Check connections.
Cycle power to the system.
The GPS receiver is unable to provide
a two-dimensional coordinate position.
Check that at least 3 satellites are in
view and that the receiver does not have
an obstructed view of the horizon.
The system must have a grower, farm,
field, and task defined in order to log
data. Create or select an active grower,
farm, field, and task.
If the "Write to Card" window is set to
"Yes" or the GPS Location window is
set to anything but "Not Installed," the
system checks for the presence of a
memory device at power ON. Insert a
memory device and cycle power to the
system.
The system detected the presence of a
memory device and then detected that
the device was removed. Data logging
will stop. The memory device must be
reinserted and power to the system
must be cycled to enable logging.
The memory stick has 90 % of its usable
memory used. Data will need to be
removed from the memory stick soon.
There is no more memory space
remaining on the memory stick. Data
will no longer be saved to the device.
A new task is automatically created to
ensure that data continues to be logged.
The current on-screen map data size
has been exceeded. Data will continue
to log to the removable memory stick
but will not be displayed. A new field
must be selected or created to view new
map data.
Perform a new area calibration for the
current grower, farm, and field (Home >
Calibration > Area).