5. Press the "Update Cal" button to adjust the stored cal-
ibration value for the current field conditions and vehi-
cle configuration.
The value in the "Measured Distance" window updates
to match the value in the "Actual Distance" window, and
a new calibration value displays.
If the updated value is out of range, a warning message
displays: "Redo calibration. See operator's manual if
problem continues."
Press the "OK" button to acknowledge and clear the
message.
Perform the procedure again with greater accuracy to
correct the problem.
6. Repeat the calibration procedure to verify accuracy.
In general, there should not be a great difference be-
tween individual runs.
Multiple runs can be averaged for greater accuracy –
sum the calibration values from each run and divide the
total by the number of runs performed.
7. Manually enter the average value in the "Distance Cal
Value" window.
Press the "Distance Cal Value" window to access the
numeric keypad.
Use the keypad to enter the average calibration value.
Press the "Enter" button on the keypad to save the av-
erage calibration value.
NOTE: The calibration values shown are for reference
only. Use the value that results from your vehicle con-
figuration operating in your field conditions.