5. Press the "Cal" (calibrate) button to update the vehi-
cle's radar calibration value.
If the difference between the value in the "Distance" win-
dow and the value in the "Radar Measured" window is
too great, a warning message displays: "Radar calibra-
tion result is out of range and will not take effect. Please
verify distance and repeat calibration."
Press the "OK" button to acknowledge and clear the
message.
Restart radar calibration.
6. Repeat this procedure at least four times and calculate
the average calibration value – sum the calibration val-
ues from each run and divide the total by the number
of runs performed.
7. Manually enter the average calibration value.
Press the "Radar Cal Value" window to access the nu-
meric keypad.
Use the keypad to enter the average calibration value.
Press the "Enter" button on the keypad to save the
value.