C8051F120/1/2/3/4/5/6/7 C8051F130/1/2/3
Table 9.1. Voltage Reference Electrical Characteristics
V
= 3.0 V, AV+ = 3.0 V, –40 to +85 °C unless otherwise specified.
DD
Parameter
Analog Bias Generator Power
Supply Current
Output Voltage
VREF Short-Circuit Current
VREF Temperature Coefficient
Load Regulation
VREF Turn-on Time 1
VREF Turn-on Time 2
VREF Turn-on Time 3
Reference Buffer Power Sup-
ply Current
Power Supply Rejection
Input Voltage Range
Input Current
118
Conditions
BIASE = 1
Internal Reference (REFBE = 1)
25 °C ambient
Load = 0 to 200 µA to AGND
4.7 µF tantalum, 0.1 µF ceramic
bypass
0.1 µF ceramic bypass
no bypass cap
External Reference (REFBE = 0)
Rev. 1.4
Min
Typ
Max
—
100
—
2.36
2.43
2.48
—
—
30
—
15
—
—
0.5
—
—
2
—
—
20
—
—
10
—
—
40
—
—
140
—
1.00
—
(AV+) – 0.3
—
0
1
Units
µA
V
mA
ppm/°C
ppm/µA
ms
µs
µs
µA
ppm/V
V
µA