CMIOU Configurations (SPARC M8-8 and SPARC M7-8 With Two PDomains)
"Controlling the Server and Domains" on page 67
■
"Understanding Server Configurations and Failover Behavior" on page 79
■
CMIOU Configurations (SPARC M8-8 and SPARC M7-8 With
Two PDomains)
Each PDomain in a SPARC M8-8 and SPARC M7-8 server that is configured with two static
PDomains can consist of up to four of the eight CMIOUs in the chassis.
The following configurations are supported on a SPARC M8-8 and SPARC M7-8 server that
has two PDomains.
CMIOU_0 and CMIOU_1 in PDomain_0 and
■
CMIOU_4 and CMIOU_5 in PDomain_1
CMIOU_0 – CMIOU_2 in PDomain_0 and
■
CMIOU_4 – CMIOU_6 in PDomain_1
CMIOU_0 – CMIOU_3 in PDomain_0 and
■
CMIOU_4 – CMIOU_7 in PDomain_1
Note -
support SPARC M8 CMIOUs. SPARC M8 CMIOUs are supported in PDomain_1 (CMIOU_4
to CMIOU_7) of the SPARC M7-8 server with two PDomains. SPARC M8 CMIOUs are not
supported in PDomain_0 (CMIOU_0 to CMIOU_3). SPARC M7 CMIOUs are not supported
in SPARC M8-8 servers. See
information.
For information about the PCIe slots that are available in each of these configurations, see
"Understanding PCIe Card Device and Service Paths" on page
Caution -
Related Information
"SPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (Two
■
PDomains)" on page 80
"Mixed CMIOU Configurations" on page 86
■
84
SPARC M8 and SPARC M7 Servers Service Manual • September 2017
The SPARC M7-8 server with two PDomains is the only SPARC M7 server that can
"Mixed CMIOU Configurations" on page 86
To prevent overheating, fill unused CMIOU slots with CMIOU filler panels.